6 Standard designation
Cements covered by this document shall be designated by at least the notation of the cement type as specified in Table 1 and the Figures 32,5, 42,5 or 52,5 indicating the strength class. In order to indicate the early strength class the letter L, N or R shall be added as appropriate.
When in the same factory a manufacturer produces different cements complying with the same standard designation, these cements receive an additional identification in the form of a number or of two lower case letters, between brackets, in order to distinguish these cements from each other. For the numbering system, this number should be 1 for the second certified cement, 2 for the next, and so on.
For the lettering system, the letters shall be chosen in such a way as to avoid confusion.
Low heat cement in accordance with 7.2.3 of EN 197-1:2011 shall be additionally designated by the notation LH.
EXAMPLE 1
Portland-composite cement CEM II/C-M containing in total a quantity of silicious fly ash (V) of between 16 % and 44 % by mass and a quantity of limestone (LL) of between 6 % and 20 % by mass and of strength class 32,5 with high early strength and a low heat of hydration is designated by:
Portland-composite cement EN 197-5 – CEM II/C-M (V-LL) 32,5 R – LH
EXAMPLE 2
Portland-composite cement CEM II/C-M containing in total a quantity of granulated blast furnace slag (S) of between 6 % and 44 % by mass and a quantity of silicious fly ash (V) of between 6 % and 44 % by mass and of strength class 42,5 with ordinary early strength and a low heat of hydration is designated by:
Portland-composite cement EN 197-5 – CEM II/C-M (S-V) 42,5 N – LH
EXAMPLE 3
Composite cement CEM VI containing in total a quantity of granulated blast furnace slag (S) of between 31 % and 59 % by mass and limestone (L) of between 6 % and 20 % by mass and of strength class 32,5 with high early strength is designated by:
Composite cement EN 197-5 – CEM VI (S-L) 32,5 R
EXAMPLE 4
Composite cement CEM VI containing in total a quantity of granulated blast furnace slag (S) of between 31 % and 59 % by mass and natural pozzolana (P) of between 6 % and 20 % by mass and of strength class 42,5 with low early strength is designated by:
Composite cement EN 197-5 – CEM VI (S-P) 42,5 L
7 Conformity criteria
For cements covered by this document the conformity criteria specified in Table 2 and in Clause 9 of EN 197-1:2011 shall apply. In particular, conformity criteria specified for “all cements” in EN 197-1:2011 shall also apply for cement covered by this document.
The conformity of cements covered by this document should be demonstrated by:
— factory production control, including product assessment, in accordance with Clause 4 of EN 197-2:2020;
— assessment of the performance of the cement in accordance with 5.1 of EN 197-2:2020;
— initial inspection of the manufacturing plant and of factory production control in accordance with 5.2 of EN 197-2:2020;
— continuing surveillance, assessment and evaluation of factory production control in accordance with 5.3 of EN 197-2:2020;
— audit-testing of samples taken at the factory/depot in accordance with 5.4 of EN 197-2:2020. Information concerning reports is given in 5.5 of EN 197-2:2020. Actions to be taken in the event of non-conformity are specified in 5.6 of EN 197-2:2020.
8 Attestation of conformity
For the attestation of conformity of cements covered by this document the procedure specified in Clause 6 of EN 197-2:2020 shall apply. When compliance with the conditions of this document is achieved, a certificate of conformity should be issued. The certificate shall include:
— name, address and identification number of the certification body;
— standard designation of the cement;
— name and address of the manufacturer or distributor and place of production;
— provisions to which the product conforms (i.e. this EN 197-5);
— conditions of validity of the certificate, where applicable;
— the number of the certificate; — name of, and position held by, the person empowered to sign the certificate.BS 197-5 pdf download.