5 Requirements
5.1 Geometrical properties
5.1.1 Length
When tested according to 7.1.1, the tolerance on length L shall be + 1,0 %, – 0,2 %.
5.1.2 Width
When tested according to 7.1.2, the tolerance on width w shall be ± 2 %.
5.1.3 Thickness
When tested according to 7.1.3, the tolerance on thickness e shall be ± 10 %.
The thickness of the corrugated bitumen sheets shall be measured including any surface relief (surface pattern) on the upper and lower sides (see Figure 4).
NOTE Due to the fact that the relief of the surfaces may be very different (e.g. from one manufacturer to the other), the measurement of the thickness will give only some descriptive information and therefore cannot be directly compared between different products.
5.1.4 Height of corrugations
When tested according to 7.1.4, the tolerance on the height of corrugations H shall be ± 6 %.
For corrugated bitumen sheets with various corrugation heights, all the declared corrugation heights shall be measured.
5.1.5 Pitch of corrugations
When tested according to 7.1.5, the tolerance on the pitch of corrugations p shall be ± 3 %.
For corrugated bitumen sheets with various pitches and/or period of corrugation, all the declared pitches and/or periods shall be measured.
5.1.6 Squareness
When tested according to 7.1.6, the squareness E shall be less than or equal to 4 mm/m.
5.2 Mechanical properties
5.2.1 Bending under downward load
When tested according to 7.2.1, the minimum load for a deflection of 1/200 of a span of 620 mm shall be:
category R ≥ 1400 N/m 2
category S > 700 N/m 2
NOTE For calculation of maximum permissible load in manufacturers’ installation guides, other methods may be used particularly in case of sheet shapes that do not allow the distributed downward load described in 7.2.1 to be applied.
5.2.2 Impact strength
When tested according to 7.2.2, the falling height with a span of 620 mm shall be:
category R = 400 mm;
category S = 250 mm.
This requirement is not relevant for external wall finishing products.
5.2.3 Tearing strength
When tested according to 7.2.3, the tear threshold value shall be greater than:
category R = 200 N;
category S = 150 N.
Where, in the case of a corrugated bitumen sheet with various corrugation heights, the manufacturer defines
which corrugation has to be used for fixing, only this corrugation has to be tested.
5.3 Physical properties
5.3.1 Water impermeability
When tested according to 7.3.1, no drop of water shall pass through the sheet after 48 h.
5.3.2 Proportion of bitumen
When tested according to 7.3.2, the bitumen content shall be equal to or greater than 40 %.
The properties are measured without any covering of granules or fine flakes.
5.3.3 Mass
When tested according to 7.3.3, the tolerance on the declared mass (expressed in kg/m 2 ) shall be ± 10 %.
5.3.4 Homogeneity of the product
When tested according to 7.3.4, there shall be no area larger than 1 cm 2 without bitumen.
5.3.5 Water absorption
When tested according to 7.3.5, the water absorption shall be less than 20 % of the mass of the sheet.
The properties are measured without any covering of granules or fine flakes.
5.3.6 Slip resistance
Due to their rough surfaces, corrugated bitumen sheets are not slippery products.
5.3.7 Load bearing
Installation guidelines shall recommend not to permit walking between the purlins (load bearing capacity is not
covered by this product standard).
5.4 Durability
5.4.1 Tearing strength after freeze/thaw ageing
When tested according to 7.4.1, the tearing strength shall not be lower than the initial threshold values (5.2.3).
5.4.2 Water impermeability after freeze/thaw ageing
When tested according to 7.4.2, no drop of water shall pass through the sheet after 48 h.
5.4.3 Thermal coefficient
When tested according to 7.4.3, the value of α shall be less than 100 x 10 -6 1/K.
5.5 Fire performance
5.5.1 Reaction to fire
This characteristic shall be declared when subject to regulatory requirements and may be declared when not subject to such requirements. Where the manufacturer wishes to make a declaration of the reaction to fire
performance of his corrugated bitumen sheets (e.g. when they are subject to regulatory requirements), the sheets shall be tested and classified in accordance with 7.5.1.
5.5.2 External fire performance
This characteristic shall be declared when subject to regulatory requirements and may be declared when not subject to such requirements. Where the manufacturer wishes to make a declaration of the external fir performance of his corrugated bitumen sheets (e.g. when they are subject to regulatory requirements), the sheets shall be tested and classified in accordance with 7.5.2.