BS EN 4674-004:2015 pdf download – Aerospace series — Electrical cables, installation — Self- wrapping shielding (EMI) protective sleeve Part 004: Open sleeve — Outside pressurized area — EMI protection 1 0 kA — Temperature range – 65 °C to 200 °C — Product standard
1 scope
This European Standard specifies the characteristics of flexible 10 kA self-wrapping shielding (EMI) protectionsleeves, to be installed mainly outside pressurized areas on electrical cables or cable bundles,made fromnickel plated copper strands and PPs (polyphenylene sulphide) monofilament.
Temperature range: -65 C to 200°℃.
2Normative references
The following documents, in whole or in part,are normatively referenced in this document and areindispensable for its application.For dated references, only the edition cited applies. For undated references,the latest edition of the referenced document (including any amendments) applies.
EN 2591-214, Aerospace series —Elements of electrical and optical connection —Test methods — Part 214:Lightning strike, current and voltage pulse
EN 2591-307,Aerospace series —Elements of electrical and optical connection—Test methods — Part 307:Salt mist
EN 2825,Aerospace series — Burning behaviour of non metallic materials under the influence of radiatingheat and flamesDetermination of smoke density
EN 2826,Aerospace series — Burning behaviour of non metallic materials under the influence of radiatingheat and flames- Determination of gas components in the smoke
EN 3475, Aerospace series – Cables, electrical, aircraft use — Test methods 1)
EN 3844-1, Aerospace series — Flammability of non metalic materials — Part 1:Small burner test, vertical —Determination of the vertical flame propagation
EN 4674-001,Aerospace series – Electrical cables, installation — Self-wrapping shielding (EMl) protectivesleeve -Part 0o1: Technical specification
EN 4674-002,Aerospace series — Electrical cables,installation — Self-wrapping shielding (EMl) protectivesleeve- Part 0o2: General and list of product standard
EN 6059,Aerospace series —Electrical cables, installation — Protection sleeves —Test methods 1)ISO4892-3, Plastics —Methods of exposure to laboratory light sources — Part 3: Fluorescent UV lamps
IEC 62153-4-3,Metallic communication cable test methods — Part 4-3: Electromagnetic compatibility(EMC)一Surface transfer impedance – Triaxial method 2)
ASTM D4894, Standard Specification for Polytetrafluoroethylene (PTFE) Granular Molding 3)
3 Terms and definitions
For the purposes of this document, the terms and definitions given in EN 4674-001 apply.
4 Required characteristics
4.1 Composition
This product is manufactured from PPS (polyphenylene sulphide) monofilaments and nickel-plated copper wire, with or without an internal protective tape.
4.2 Dimensions and mass of the sleeve
See Figures 1 and 2, Tables 1 and 2.
4.3 Colour, materials and tracer line identification
4.3.1 Colour, tracer line and sleeve identification
See EN 4674-001.
4.3.2 Internal mechanical protection tape
The sleeve can be delivered with an internal mechanical protection tape according to ASTM D4894 Type IV,Grade 2 for electrical insulation between the cables and the metallic flat braid; see Table 3.
4.3.3 Size identification
To identify each sleeve size, no specific tracer shall be specified. The size can be verified by the installation of the sleeve on a mandrel or bundle and the tracer line.
4.4 Electrical characteristics for EMI protection
4.4.1 Electrical resistance requirement
In accordance with Table 4.