BS ISO 4548-5:2020 pdf download – Methods of test for full-flow lubricating oil filters for internal combustion engines Part 5: Test for cold start simulation and hydraulic pulse durability This document specifies a method of testing the ability of full-flow lubricating oil filters manufactured with metal pressure vessel materials for internal combustion engines to withstand an internal pressure surge. Normally surges occur when an engine is started from cold, and cyclic internal pressure variations experienced during operation. These tests are intended for application to spin-on type filters and detachable filters with disposable elements. The tests can be applied to other filters, if thought applicable, by agreement between the filter manufacturer and the purchaser. NOTE This test is not intended to replace simulated environmental testing (e.g. at very low temperatures). If such testing is required, it will be the subject of negotiation between the supplier and customer. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 1219-1, Fluid power systems and components — Graphical symbols and circuit diagrams — Part 1: Graphical symbols for conventional use and data-processing applications ISO 4548-1, Methods of test for full-flow lubricating oil filters for internal combustion engines — Part 1: Differential pressure/flow characteristics 3 Terms, definitions and graphical symbols 3.1 Terms and definitions For the purposes of this document, the terms and definitions given in ISO 4548-1 apply. ISO and IEC maintain terminological databases for use in standardization at the following addresses: — ISO Online browsing platform: available at https:// www .iso .org/ obp — IEC Electropedia: available at http:// www .electropedia .org/ 3.2 Graphical symbols For the purposes of this document, the graphical symbols given in ISO 1219-1 apply. 4 Operational characteristics to be tested Filters are subjected in service to pressure fluctuations caused by either engine cold starting conditions or hydraulic pulse events during normal operation. The test specified in Clause 8 can be performed at a range of pressures on separate filters to simulate in-service conditions and verify the capability of the filter canister and seal to withstand these pressures. 5 Test rig See Figure 1 as an example of a typical test circuit. An alternative test rig, which produces...

Download Address

  • Download