BS 3475-411:2018 pdf download – Aerospace series – Cables, electrical, aircraft use – Test methods Part 411: Resistance to fluids This European Standard specifies two methods of determining the fluid resistance of a finished cable. Method 1: occasional contamination. Method 2: contamination test. It shall be used together with EN 3475-100 and EN 3909. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3475-100, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 100: General EN 3475-201, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 201: Visual examination EN 3475-203, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 203: Dimensions EN 3475-302, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 302: Voltage proof test EN 3475-405, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 405: Bending at ambient temperature EN 3475-503, Aerospace series — Cables, electrical, aircraft use — Test methods — Part 503: Scrapeabrasion EN 3909, Aerospace series — Test fluids for electrical and optical components and sub-assemblies ISO 1817, Rubber, vulcanized or thermoplastic — Determination of the effect of liquids MIL-PRF-87937D, Performance specification: cleaning compound, aerospace equipment 1) ASTM D740, Standard Specification for Methyl Ethyl Ketone 2) AMS 1476B, Aircraft toilet flush fluid 2) 3 Terms and definitions No terms and definitions are listed in this document. ISO and IEC maintain terminological databases for use in standardization at the following addresses: • IEC Electropedia: available at http://www.electropedia.org/ • ISO Online browsing platform: available at http://www.iso.org/obp 4 Test fluids Unless otherwise specified in the product standard, all fluids listed in EN 3909 are mandatory. 5 Procedures 5.1 General 5.1.1 Unless specified in the product specification method 2 shall be used. 5.1.2 For each fluid to be tested, take two (2) clean specimen at least off 1 m in length from a finished cable. Where large cables are being tested a single specimen may be divided into two (2) after fluid exposure if the resulting pieces are of sufficient length to allow the post tests to be correctly carried out. Strip approximately 25 mm of both ends of each...

Download Address

  • Download