BS ISO 5834-2:2019 pdf download – Implants for surgery — Ultra-high- molecular-weight polyethylene Part 2: Moulded forms This document specifies the requirements and corresponding test methods for moulded forms, e.g.sheets and rods, made from ultra‑high‑molecular‑weight polyethylene (UHMWPE) for use in the manufacture of surgical implants. This document is not applicable to direct-moulded (near net shape), irradiated or finished products or products manufactured from polyethylene blended with additives or by blending different forms of polyethylene. 2 Normative references The following documents are referred to in the text in such a way that some or all of their content  constitutes requirements of this document. For dated references, only the edition cited applies. Forundated references, the latest edition of the referenced document (including any amendments) applies. ISO 1183‑1:2012, Plastics — Methods for determining the density of non-cellular plastics — Part 1:Immersion method, liquid pyknometer method and titration method ISO 5834‑1, Implants for surgery — Ultra-high-molecular-weight polyethylene — Part 1: Powder form ASTM F648, Standard specification for ultra-high-molecular-weight polyethylene powder and fabricated form for surgical implants 3 Terms and definitions No terms and definitions are listed in this document. ISO and IEC maintain terminological databases for use in standardization at the following addresses: — ISO Online browsing platform: available at https://www.iso.org/obp — IEC Electropedia: available at http://www.electropedia.org/ 4? Classification The material moulded from Type 1, Type 2 or Type 3 powder as defined in ISO 5834‑1 shall be classified as Type 1, Type 2 or Type 3 respectively. 5 Material The moulded material shall be made from UHMWPE powder in accordance with the requirements of ISO 5834‑1. 8.2 Density The density shall be measured by means of method A (immersion method) specified in ISO 1183-1, using at least three specimens. The mean of the results on the three test specimens shall be within the limits given in Table 1 8.3 Tensile testing 8.3.1 General The tensile test shall be conducted as specified in ASTM F648. At least five test specimens shall be tested. 8.3.2 Tensile stress at yield The tensile stress at yield, Oy shall be determined in accordance with 8.3.1. The mean of the results on the five test specimens shall not be less than the values given in Table 1. 8.3.3 Tensile stress at break The tensile stress at break, OR, shall be determined in accordance with 8.3.1. The mean of the results on the five test specimens shall not be less...

Download Address

  • Download