BS EN-500-6:2006 pdf download – Mobile road construction machinery — Safety — Part 6: Specific requirements for paver-finishers 5 Safety requirements and/or protective measures 5.1 Lighting, signalling and marking lights and reflex-reflector devices 5.2 of EN 500-1:2006 applies. 5.2 Operation and handling 5.3 of EN 500-1:2006 applies. 5.3 Operator’s station 5.4 of EN 500-1:2006 applies with the following exception: 5.4.1 of EN 500-1:2006, fifth and sixth indent, applies only for forward measurement; 5.4.2 of EN 500-1:2006, first paragraph, does not apply for paver-finishers. 5.4 Operator’s seat 5.5 of EN 500-1:2006 applies. 5.5 Controls and indicators 5.6 of EN 500-1:2006 applies with the following addition: the extending or closing of the telescopic screed shall not be induced simultaneously from both the operator’s station and the remote control area. Controls for the regulation of the telescopic screeds shall be designed in such a manner as to ensure that they return to neutral when released (hold-to-run control). 5.6 Starting 5.7 of EN 500-1:2006 applies. 5.7 Stopping 5.8 of EN 500-1:2006 applies with the following addition: braking systems of rubber-tyred paver-finishers shall comply with Annex A. 5.8 Access systems to operator’s station and to maintenance points 5.9 of EN 500-1:2006 applies with the following exception and addition: the height of the first step (600 mm) for access to the operator’s position can be exceeded in transport position. 5.9 does not apply for access systems leading to service points in the area of the material hopper. Walkways shall be fitted to the screed sections and shall cover the operating width of the screed. 5.9 Protection 5.10 of EN 500-1:2006 applies with the following addition: screeds shall be provided with a locking device to ensure safe elevation. The spreader augers from which mechanical hazard emanates within the width of the basic machine shall be fitted with fixed guards according to 3.2 of EN 953:1997, e.g. by gratings. When the spreader augers extend beyond the width of the basic machine, they shall at least be protected by guard-rails. When paver-finishers are designed for use on rails, all wheels in each direction of travel shall be provided with footguards. The distance between the foot-guards and upper edge of the rail shall not exceed 20 mm. 5.10 Pressurised systems 5.11 of EN 500-1:2006 applies. 5.11 Fire protection 5.12 of EN 500-1:2006 applies. 5.12 Hot surfaces 5.13 of EN 500-1:2006 applies. 5.13 Signal devices and warning signs 5.14 of EN...

Download Address

  • Download